| Flow: |
1-175 GPM (3 - 662 LPM) |
| Pressure: |
0-150 PSI (0 - 10.3 BAR) |
| Performance: |
Positive displacement. Little flow decrease with
pump pressure increase. Flow increases with speed increase. |
| Suction Lift (water): |
0-20 Ft. below pump level (0-6.1 meters) |
| Liquid Cleanliness and Viscosity: |
Close tolerances require clean liquids. Viscous
liquids require lower pump speeds. |
| Liquid Compatibility: |
Most common liquids and compatible chemicals. |
| Noise: |
Metal to metal gear noise very evident. metal to
plastic gear noise evident. |
| Power Required: |
Power demand increases with speed and pressure. |
| Discharge Line: |
Positive displacement relief valve necessary to
shut off. |
| Bearing Lubrication Required: |
Carbon bearings - No
Bronze bearings - No |
| Temperature: |
Carbon bearings: - 40 to 300 degrees F (-40 degrees
C to 150 degrees C)
Bronze bearings: -40 to 400 degrees F (-40 degrees C to 208 degrees C) |
| Seal Arrangement: |
Packing, Lip, Mechanical |
| Types: |
Close Coupled & Pedestal |
Stainless
Steel/Alloy C
| Flow: |
0-23 GPM (0 - 87 LPM) |
| Pressure: |
0-100 PSI (0 - 6.9 BAR) |
| Performance: |
Positive displacement. Little flow decrease with
pump pressure increase. Flow increases with speed increase. |
| Suction Lift (water): |
0-20 ft. below pump level (0 - 6.1 meters) |
| Liquid Cleanliness and Viscosity: |
Close tolerances require clean liquids. Viscous
liquids require lower pump speeds. |
| Liquid Compatibility: |
Chemicals and compatible liquids. |
| Noise: |
Metal to metal gear noise very evident. Metal to
plastic gear noise quieter. Plastic to plastic gear noise most quiet. |
| Power Required: |
Power demand increases with speed and pressure. |
| Discharge Line: |
Positive displacement relief valve necessary to
shut off. |
| Bearing Lubrication Required: |
No |
| Temperature: |
-40 degress F. to 400 degrees F. (-40 degrees C to
208 degrees C) |
| Seal Arrangement: |
Mechanical or packing |
| Types: |
Close coupled & Pedestal |
| Flow: |
0-35 GPM (0-132.5 LPM) |
| Pressure: |
0-500 PSI (0 - 34.5 BAR) |
| Performance: |
Positive displacement. Little flow decrease with
pump pressure increase. Flow increases with speed increase. |
| Suction Lift (water): |
0-20 ft. below pump level (0 - 6.1 meters) |
| Liquid Cleanliness and Viscosity: |
Close tolerances require clean liquids. Viscous
liquids require lower pump speeds. |
| Liquid Compatibility: |
Petroleum products, solvents and oils,
non-corrosive liquids, liquid propane. |
| Noise: |
Helical gear design quiet. |
| Power Required: |
Power demand increases with speed and pressure. |
| Discharge Line: |
Positive displacement relief valve necessary to
shut off. |
| Bearing Lubrication Required: |
Carbon bearings - No |
| Temperature: |
-40 degrees F. to 250 degrees F. (-40 degrees C to
122 degrees C) |
| Seal Arrangement: |
Mechanical or packing |
| Type: |
Close coupled & Pedestal |
PPS Plastic
(Polyphenelene Sulphide)
| Flow: |
0-8 GPM (0-30.3 LPM) |
| Pressure: |
0-100 PSI (0 - 6.9 BAR) |
| Performance: |
Positive displacement. Little flow decrease with
pump pressure increase. Flow increases with speed increase. |
| Suction Lift (water): |
0-20 ft. below pump level (0 - 6.1 meters) |
| Liquid Cleanliness and Viscosity: |
Close tolerances require clean liquids. Viscous
liquids require pump speeds. |
| Liquid Compatibility: |
Most corrosive liquids and chemicals. |
| Noise: |
Plastic gear noise most quiet. |
| Power Required: |
Power demand increases with speed and pressure. |
| Discharge Line: |
Positive displacement relief valve necessary to
shut off. |
| Bearing Lubrication Required: |
Carbon bearings - No |
| Temperature: |
-20 degrees F. to 180 degrees F. (-29 degrees C -
82 degrees C) |
| Seal Arrangement: |
Mechanical, lip, or packing |
| Types: |
Close coupled & Pedestal |
|
|